k factor pipe fittings in canada

Products - Grooved Couplings & Fittings - Mechanical Pipe

Victaulic mechanical joining & piping system products include grooved pipe couplings, fittings & adaptors, flow control valves, equipment modules (ie: AHU drops) and pipe end preparation tools. Our reliable & efficient pipe joining products will help you finish your project on time & under budget.

K Factor For Reducer And Friction Factor For Material

Feb 28, 2012· K Factor For Reducer And Friction Factor For Material Other Than Steel - posted in Industrial Professionals: Dear Forum Meers,For calculating the K factor for a reducer/ expander and friction factor for materials other than steel, I have below two questions: For any reducer, Crane TP-410 says that the K value is independent of size ie. It doesn’t depend on the friction factor.

Friction Losses in Pipe Fittings Resistance Coefficient K

Example: Determine L (friction loss in pipe fittings in terms of equivalent length in feet of straight pipe). Assume a 6" angle valve for Schedule 40 pipe size. Select the appropriate K value for such and select D and f for Schedule 40 pipe from the table below where K is the pipe diameter in feet. Pipe Size Inches Sch. 40 D feet f Pipe Size Inches

Insulation Ratings: Calculating R Factor, K Factor & C Factor

Jun 14, 2011· The R factor pulls together all of the information of the other factors and makes it easy to judge the effectiveness of insulating material. The R factor of insulation can be found most easily of the insulation factors discussed, and it is the most popular indior of a material’s insulator properties.

Star Pipe Products - Ductile Iron Pipe Fittings, Joint

Star Pipe Products has a complete line of Ductile Iron Compact and Full Body Mechanical Joint (MJ) Fittings, Full Body Flange Fittings, Compact Push-On Fittings, Fabrior Products, Accessories and a complete line of coatings and linings including Fusion Bonded Epoxy and Protecto 401™ Ceramic Epoxy. Check out our new online submittals, as well.

Resistance coefficient K for fittings

You can use the calculator for resistance coefficient (or resistance factor) K calculation of fittings. Resistance coefficient K is proportional coefficient between pressure drop (head loss) and square velocity of fluid flowing through valves and fittings like an elbow, bend, reducer, tee, pipe entrance, and pipe …

K Factor Calculator for fittings - Pipe Flow Calculations

Apr 19, 2013· Also, looking at the K factor calculation for "sudden and gradual contraction" in the "K-Factor=Fittings" calculator: If I enter the data into the calculator as follows: Angle = 60 deg. D1 = 15mm D2 = 25mm I get the result: K1 = .22627416; K2 = 1.7459426 If I do the calculation manually per the Flow Theory Page "Flow in valves and fittings":

PVC Resistance Coefficient, K - Pipelines, Piping and

Dec 06, 2004· This is sometimes confusing when using the Crane 410 procedures. The way Crane correlates the K value it does seem to be affected by the friction factor - but this is just a "standard" friction factor that Crane have chosen to use and it has nothing to do with the actual friction factor (or pipe roughness) of the actual material.

Pipe Fitters Handbook

ANVIL® PIPE FITTERS HANDBOOK 5 Gruvlok Installation Pipe and Flange Data Weld Fitting and Steel Flange Data Table of Contents Gruvlok Tech. Data Bolt Templates General Welding Information Conversions Drop Nipple and Tee-Let Installation Pipe Thread Standards GRUVLOK® INSTALLATION AND ASSELY Figures 7000 & 7001 Couplings 1. Check & Lubrie

Understand How Valves & Fittings Affect Head Loss

Understand How Valves & Fittings Affect Head Loss by Ray Hardee (Engineered Software, Inc.) This series discusses valves and fittings and evaluates how these devices affect the operation of piping systems. Part 1 (Pumps & Systems, May 2015) covered head loss, K value and L/D coefficient. You can read part 1 here. C V Coefficient The C V

Camlock Fittings – Camlock Couplings – Cam and Groove Fittings

Camlock Fittings By Pro Flow Dynamics. Pro Flow Dynamics has created this website specifically dedied to all your cam lock fitting needs. Providing to customers all over the United States and parts of Canada and Mexico, we supply quality camlock fittings and camlock couplings.

Schedule 80 PVC and CPVC Molded Installation Fittings

is the nuer of pulses a sensor will generate for each engineering unit of fluid that passes the sensor. K-Factors for water are listed below in U.S. gallons and liters. For example, in a 1 inch SCH 80 PVC pipe, the FP-5100 paddlewheel generates 172.07 pulses per gallon of water passing the rotor. K-Factors are for Schedule 80 pipe.

Modeling a Reducing Elbow - Engineered Software Knowledge

If you need to include a reducing elbow in your PIPE-FLO model, but don’t have any K factor data, you can use a coination of a reducer and elbow. The standard table shipped with PIPE-FLO contains all of the valves and fittings found in the Crane Technical Paper No. 410. The Crane paper does not include K factor data for reducing elbows.

Solved: Custom K factor calculation for pipe fittings

Re: Custom K factor calculation for pipe fittings. Hi Jeremy thanks for your reply, I have been working with js1900 on this. We had looked through those calculations in Revit help which are well explained for pipes.

Reducer K value - EnggCyclopedia

Equivalent length, L eq = K × (D/4f) where, K is the K value for a fitting (or for all fittings coined) D is the pipe diameter f is the Fanning friction factor. You can use this equivalent length is used in the above Darcy''s equation, to calculate the frictional pressure losses across the pipe run including all the fittings and valves in the

Losses in Pipe Fittings and Valves ~ ME Mechanical

Jun 30, 2016· Generally for valves and fittings, manufacturers provide loss coefficient ‘K’ value. It may also be calculated from the equivalent length concept: K = fL e /D, where L e is the equivalent pipe length that has the same frictional loss, f is the Moody friction factor (Darcy-Weisbach friction factor) and D is inner diameter of the pipe.

Pipe Fittings & Valves Database with K factors

K= K factor associated with a specific type and size of fitting v = fluid velocity (m/s or ft/s) g = 9.806 m/s² or 32.174 ft/s² Pipe Fittings Database. Within the Pipe Flow Wizard software the type and quantity of bends, valves and other fittings associated with the pipe can be set by amending the quantity values on the ''Pipe fittings'' screen.

Products - Grooved Couplings & Fittings - Mechanical Pipe

Victaulic mechanical joining & piping system products include grooved pipe couplings, fittings & adaptors, flow control valves, equipment modules (ie: AHU drops) and pipe end preparation tools. Our reliable & efficient pipe joining products will help you finish your project on time & under budget.

Some Friction Loss Tables

Example: Determine L (friction loss in pipe fittings in terms of equivalent length in feet of straight pipe). Assume a 6" angle valve for Schedule 40 pipe size. Select the appropriate K value for such and select D and f for Schedule 40 pipe from the table below where K is the pipe diameter in feet.

Insulation Ratings: Calculating R Factor, K Factor & C Factor

Jun 14, 2011· The R factor pulls together all of the information of the other factors and makes it easy to judge the effectiveness of insulating material. The R factor of insulation can be found most easily of the insulation factors discussed, and it is the most popular indior of a material’s insulator properties.

K-factor charts | GF Signet 8150 Battery-Powered Flow

GF Signet 8150 Battery-Powered Flow Totalizer User Manual • K-factor charts • GF Signet Tools Brands. GF Signet manuals. Tools. 8150 Battery-Powered Flow Totalizer. Manual K-factor charts – GF Signet 8150 Battery-Powered Flow Totalizer User Manual Page 17. Text mode ; Original mode COPPER TEE FITTINGS ON COPPER PIPE SCH K. 1/2

Pressure drop in pipe fittings and valves | equivalent

In long pipelines most of the pressure drop is due to the friction in the straight pipe, and the pressure drop caused by the fittings and valves is termed the "minor loss". As pipes get shorter and more complied the proportion of the losses due to the fittings and valves gets larger, but by convention are still called the "minor losses".

Schedule 40 PVC - GF Canada - GFPS

GF Harvel PVC Schedule 40 pipe and fittings exhibit consistent quality with uniform properties. GF Harvel uses its own custom blends of PVC compounds to offer you two pipe brand choices to ensure that desirable physical properties are maintained for various appliions.

Pipe Fitting Losses - CheCalc

Pipe Fitting Losses Pressure loss in a pipe due to fittings such as elbows, tees, valves, expanders and reducers based on 3K and 2K method.

Schedule 40 PVC - GF Canada - GFPS

GF Harvel PVC Schedule 40 pipe and fittings exhibit consistent quality with uniform properties. GF Harvel uses its own custom blends of PVC compounds to offer you two pipe brand choices to ensure that desirable physical properties are maintained for various appliions.

VK467 - Residential Upright Sprinkler (K4.9) | Viking

The Freedom®VK467 residential upright sprinkler has a K factor of 4.9 (71) and is approved for up to a 16 x 16 ft. (4,9 m x 4,9 m) area of coverage. The Model VK467 is cULus Listed for installation in any type of residential occupancy, and is particularly well-suited for loft-style residential appliions where the sprinkler system’s piping